Configure the FrontRange HEAT Discovery connector
The HEAT Discovery connector uses a database connection (SQL). The Snow Integration Connector for HEAT Discovery is configured in Snow Integration Manager (SIM). For more information on SIM, see Snow Integration Manager.
Prerequisites
A user account with read-only access to the HEAT Discovery database.
In the HEAT client, configure the executable file names to be included in the Inventory Settings Software Files tab via the Include/Exclude from Inventory quick action.
Procedure
-
In the Server, enter the name of the SQL server where the HEAT Discovery database resides.
-
Select one of the following authentication methods:
-
In the User id and Password, enter credentials for an SQL user account with read-only access to the HEAT Discovery database.
-
To use Windows integrated security to access the HEAT Discovery database, select the Use integrated security.
-
-
In the Database list, select the HEAT Discovery database to connect to.
-
In the Timeout (sec), set a timeout for the database connection.
-
To verify the connection, select Test connection.
-
In the Initial aggregation length, select the number of months for the initial aggregation of inventory data.
-
To reset an ongoing incremental aggregation, select Clear Last Aggregation Date.
-
Optional: Enter a site Id for this connector.